Return the mount to Zero Position after balance, i.e.
the CW shaft points to ground and telescope is at the
highest position.
Turn Gear Switch Knob 90 degree again to LOCK
position to re-engage the worm to the worm wheel.
Retighten the Gear Switch Locking Screw.
CAUTION: The balance process MUST be done
with Gear Switch at OPEN position! Otherwise it
might damage the worm system.
8. Connect Cables
: Connect DEC unit to the main
control unit with a short, straight RJ11 cable. Connect
the Go2Nova
®
8408 hand controller to the HC port on
the main unit. Plug 12V DC power supply into the
POWER socket. The power indicator on the main unit
will be on when the power switch is turned on.
9. Polar Alignment:
In order for an equatorial mount to
track properly, it has to be accurately polar aligned.
Take off the Polar Axis Cover and Polar Scope Cover.
Look through the polar scope eyepiece to locate the
Polaris. Slightly turn tripod Center Rod Knob to loosen
the mount head. Adjust the Azimuth Adjustment
Knobs to do a fine adjustment of the mount to center
the polar star in the azimuth direction. Tighten the
Center Rod Knob to secure the mount. Slightly loosen
two Latitude Locking T-bolts on the side of the mount,
turning the Latitude Adjustment Knob to adjust the
latitude (altitude). Re-tighten the locking screws.
Polar Axis Cover
Polar Scope Cover
Polar Axis (R.A. axis)
Azi. Adj. Knob
Lat. Adj. Knob
Lat. Locking T-bolt
If the mount is equipped with iOptron’s AccuAligning
TM
Polar Scope, you can do a fast and accurate polar
alignment.
Quick Polar Alignment
(1) Connect polar scope LED cable between Reticle
plug located on the main unit and the LED socket
at the bottom of the DEC axle. The illumination
intensity can be adjusted using the HC via “Set
Polar Scope Light” function under “Set Up
Controller” menu.
Polar Scope LED
(2) Pressing the MENU button, then select “Align
and “Pole Star Position” to display the Polaris
Position on the LCD screen, as indicated in the
left of the following figure. For example, May 30,
2010, 20:00:00 at Boston, US (alt N42º30’32” and
long W71º08’50”), 300 min behind UT, the Polaris
Position are 1h26.8m and 41.5m
(If you are located at south hemisphere, Sigma
Octantis will be used as the reference for polar
alignment.)
(3) Using Azimuth Adjustment Knob and Latitude
Adjustment Knob to adjust the mount in altitude
and azimuth directions and put the Polaris in
same position on the Polar Scope Dial as
indicated on the HC LCD, as shown in Right of the
above figure.
If the mount is not equipped with a polar scope or the
pole star cannot be seen, you can use Polar
Alignment Procedure.
(1) Level the ZEQ25 mount and set it at Zero Position.
Make sure the telescope is parallel to the pole
axis (R.A. axis) of the mount. If a finder scope is
used, adjust it to be parallel to the telescope
optical axis. Set correct R.A. and DEC back lash
numbers. An eyepiece with cross hairs is
recommended.
(2) Power on the mount. Pressing the MENU button,
then select “Align” and “Polar Alignment”. The
HC will display the azimuth and altitude position of
several bright stars near meridian. Select one that
is visible from the site as aligning Star A. Follow
the instruction to move the Star A to the center of
the eyepiece with the combination of Latitude
Adjustment Knob and “” or “” button. Press
ENTER to confirm. Then select a bright star that is
close to the horizon as aligning Star B. Center it
Page view 3